PCL
4 products from 4 makers. Most documented first. Select a column to sort, a product to see its values, print settings and documents.
4 products
Key
- set apart: test bar not described as printed, or no stated load
- converted price
- not published
How the numbers are worked out
3D4Makers Facilan PCL100Strength XY, MPa45Modulus XY, GPa0.35Izod notched, kJ/m²8HDT 0.45, °C57Price, CAD/kg234Nozzle, °C130–170Bed, °C30–45Chamber, °C—Drying, °C, h—
3D4Makers Facilan PCL1003D4Makers
Published values
| Property | As published | Conditions | On the Overview |
|---|---|---|---|
| 3D4Makers, Facilan™ PCL 100 Filament6 valuesUnless a row says otherwise: specimen not stated | |||
| Tensile modulus orientation not stated | 350 MPap. 1: Tensile Modulus | no standard stated | not in the median: set apart (never used to pass), test bar not described as printed |
| Tensile strength (yield or break not stated) orientation not stated | 45 MPap. 1: Tensile Strength | printed specimen (implied by the document), no standard stated | in the median |
| Elongation at yield orientation not stated | 15 %p. 1: Elongation at Yield | no standard stated | listed under other properties |
| Izod impact strength orientation not stated | 8 kJ/m2p. 1: IZOD Impact Strength (notched) | printed specimen (implied by the document), no standard stated | in the median |
| Hardness | 46 Shore Dp. 1: Shore D Hardness | no standard stated | in the median |
| Glass transition temperature | -60 °Cp. 1: glass transition temperature | no standard stated | in the median |
| 3D4Makers, Technical Data Sheet 3D Printing Filament Facilan™ PCL1004 valuesThe same values also in 3D4Makers, Facilan™ PCL 100 Filament.Unless a row says otherwise: printed specimen (implied by the document) | |||
| Flexural modulus orientation not stated | 380 MPap. 1: Flexural Modulus | ISO 178 | in the median |
| Flexural strength orientation not stated | 18 MPap. 1: Flexural Strength | ISO 178 | in the median |
| HDT at 0.45 MPa | 57°Cp. 1: Heat Deflection Temperaturealso in 3D4Makers, Facilan™ PCL 100 Filament | ISO 75As the sheet prints it: ISO 75 B**; heating rate=120 K/h | in the median |
| Density | 1.1 g/cm³p. 1: Density | specimen not stated, ISO 1183As the sheet prints it: ISO1183-1 | |
Print settings
- Nozzle
- 130–170 °Cown data sheet
- Bed
- 30–45 °Cown data sheet
- Heated chamber
- not stated
- Drying
- not stated
- Hardened nozzle
- not stated
Its 3 print profiles, in the documents' words
- Nozzle 130-170°C; Bed 30-45°C3D4Makers, Technical Data Sheet 3D Printing Filament Facilan™ PCL100p. 1: Recommended printing settings: NozzleTemperature; p. 1: Bed Adhesion
- Nozzle 130°C (130 to 170°C); Bed 30-45°C3D4Makers, Facilan™ PCL 100 Filamentp. 1: Print Settings: Print Temperature; p. 1: Bed Temperature; p. 1: Adhesion
- Nozzle 130°C (130 to 170°C); Bed 30-45°C3D4Makers, Facilan™ PCL 100 Filament | 3D4Makers | 3D Printingp. 1: Print Settings: Print Temperature; p. 1: Bed Temperature; p. 1: Adhesion
Price
234 CAD/kgits one regular price in the sample
1 listing
- filamentworld.de: 234 CAD/kg3D4Makers - Facilan - PCL 100 Filament - Natur - 1.75 mm - 0,75 kg (SKU PCL175XNAT)in its price; filamentworld.de (European storefront) lists 130 EUR including 19% VAT for 0.75 kg: 146 EUR/kg before VAT, × 1.6084 CAD per EUR (Bank of Canada, 29 Sep 2026). Used only where no Canadian shop in the sample sells the product. Shipping, duty and Canadian stock are not included.; seen 7 Oct 2026
Its 4 documents
What the maker says (11)
- Good for
Facilan™ PCL 100 it is perfect for high-value applications such as medical research.
3D4Makers, Facilan™ PCL 100 Filamentp. 1 - Good for
Our customers use our PCL for research into artificial trachea, smart materials, scaffolds for tissue engineering, bioabsorbable implants, drug-loaded implants and other cutting-edge applications.
3D4Makers, Facilan™ PCL 100 Filamentp. 1 - Good for
Facilan™ PCL 100 is used by many leading universities and research centers worldwide for bleeding edge work in bioprinting and patient specific medical research.
3D4Makers, Facilan™ PCL 100 Filamentp. 1 - Good for
3D4Makers Polycaprolactone Facilan™ PCL 100 is one of the most extensively used bioprinting and medical 3D printing research materials worldwide.
3D4Makers, Facilan™ PCL 100 Filamentp. 1 - Benefits
Facilan™ PCL 100 is very flexible and tough
3D4Makers, Facilan™ PCL 100 Filamentp. 1 - Adhesion between layers
The material has an amazing adhesion between layers which results in great improvement of the impact resistance, strength, durability, and printability.
3D4Makers, Facilan™ PCL 100 Filamentp. 1 - Printing advice
Due to the low melting point, of Facilan™ PCL100 it can be reshaped after 3D printing in water with a temperature of 55 °C.
3D4Makers, Facilan™ PCL 100 Filamentp. 1 - Pitfalls and limitations
Recommended restrictions Do not use in medical applications involving permanent implantation in the human body.
3D4Makers, Facilan™ PCL 100 Filamentp. 1 - Printing advice
Note: Add M302 S120 into the beginning of the g-code to allow cold extrusion, below 170°C
3D4Makers, Facilan™ PCL 100 Filamentp. 1 - Printing advice
Extra: Minimum Layer Time considerably +/- 60 sec minimum, highly dependent of model size and complexity and enabled Lift Head.
3D4Makers, Facilan™ PCL 100 Filamentp. 1 - Supports and removal
Support : If PVA or breakaway Support = enabled; Support overhang angle = 0°; Enable Prime Tower = Enabled. Support with Facilan Ortho onto itself: not recommended
3D4Makers, Facilan™ PCL 100 Filamentp. 1
Filament2Print BioFil - PCLStrength XY, MPa45Modulus XY, GPa0.35Izod notched, kJ/m²8HDT 0.45, °C57Price, CAD/kg—Nozzle, °C95–130Bed, °C40–50Chamber, °CnoneDrying, °C, hdry first
Filament2Print BioFil - PCLFilament2Print
Published values
| Property | As published | Conditions | On the Overview |
|---|---|---|---|
| Filament2Print, TECHNICAL DATA SHEET BioFil - PCL10 valuesUnless a row says otherwise: specimen not stated | |||
| Tensile modulus orientation not stated | 350 MPap. 1: Tensile modulus | ISO 527 | not in the median: set apart (never used to pass), test bar not described as printed |
| Tensile strength (yield or break not stated) orientation not stated | 45 MPap. 1: Tensile strength | ISO 527 | not in the median: set apart (never used to pass), test bar not described as printed |
| Elongation at yield orientation not stated | 15 %p. 1: Elongation @Yield | ISO 527 | listed under other properties |
| Flexural modulus orientation not stated | 380 MPap. 1: Flexural Modulus | ISO 178 | not in the median: set apart (never used to pass), test bar not described as printed |
| Flexural strength orientation not stated | 18 MPap. 1: Flexural Strength | ISO 178 | not in the median: set apart (never used to pass), test bar not described as printed |
| Izod impact strength | 8 kJ/m²p. 1: Notched Izod Impact Strength | ISO 180As the sheet prints it: ISO 180-1 | not in the median: set apart (never used to pass), test bar not described as printed |
| Hardness | 46 Shore Dp. 1: Shore D Hardnes | ISO 868 | in the median |
| HDT at 0.45 MPa | 57 °Cp. 1: Heat deflection temperature | ISO 75As the sheet prints it: ISO 75 B | not in the median: set apart (never used to pass), test bar not described as printed |
| Glass transition temperature | -60 °Cp. 1: Glass transition temperature | no standard stated | in the median |
| Density | 1.1 g/cm3p. 1: Density | ISO 1183As the sheet prints it: ISO 1183-1 | |
Print settings
- Nozzle
- 95–130 °Cown data sheet
- Bed
- 40–50 °Cown data sheet
- Heated chamber
- not requiredown data sheet
- Drying
- required, schedule not statedown data sheet
- Hardened nozzle
- not stated
Its 2 print profiles, in the documents' words
- Drying recommended to dry the material prior to usage and to 3D print it directly from a dry boxFilament2Print, TECHNICAL DATA SHEET BioFil - PCLp. 1: Storage and handling
- Nozzle ± 95 – 130° C; Bed ± 40 – 50° CFormFutura, BioFil - PCLp. 1: General printing guidelines
Price
Not in the price sample.
Its 3 documents
What the maker says (9)
- Good for
It is perfect for orthopedic, orthotic, and biomedical applications.
Filament2Print, TECHNICAL DATA SHEET BioFil - PCLp. 1 - Good for
Bonding textiles with insoles, midsoles, or other brace or shoe parts.
Filament2Print, TECHNICAL DATA SHEET BioFil - PCLp. 1 - Good for
Insoles and midsoles.
Filament2Print, TECHNICAL DATA SHEET BioFil - PCLp. 1 - Good for
Parts for prothesis.
Filament2Print, TECHNICAL DATA SHEET BioFil - PCLp. 1 - Benefits
Users can reshape 3D printed parts in warm water at 55°C temperature.
Filament2Print, TECHNICAL DATA SHEET BioFil - PCLp. 1 - Benefits
PCL has an excellent adhesion to textiles.
Filament2Print, TECHNICAL DATA SHEET BioFil - PCLp. 1 - Benefits
This filament biodegrades completely in soil, water, and via home composting.
Filament2Print, TECHNICAL DATA SHEET BioFil - PCLp. 1 - Benefits
Compliant with EN13432 compostability standards.
Filament2Print, TECHNICAL DATA SHEET BioFil - PCLp. 1 - Moisture sensitivity
To obtain the best parameters of the printed object, it is recommended to dry the material prior to usage and to 3D print it directly from a dry box.
Filament2Print, TECHNICAL DATA SHEET BioFil - PCLp. 1
SUNLU PCLStrength XY, MPa—Modulus XY, GPa—Izod notched, kJ/m²—HDT 0.45, °C—Price, CAD/kg—Nozzle, °C75–85Bed, °C20–40Chamber, °CnoneDrying, °C, h40–501 h
SUNLU PCLSUNLU
Published values
| Property | As published | Conditions | On the Overview |
|---|---|---|---|
| SUNLU, TECHNICAL DATA SHEET ISO PCL5 valuesThe same values also in SUNLU, SUNLU PCL official product page (Chinese) and SUNLU, SUNLU PCL 产品资料 / Product information.Unless a row says otherwise: printed specimen | |||
| Melting temperature | 58-60 ℃p. 1: Melting Temperature ISO 11357-3 10 ℃/min ℃ | ISO 11357As the sheet prints it: ISO 11357-3 | |
| Decomposition temperature | 300 ℃p. 1: @5%Decomposition Temp. ISO 11358 20 ℃/min ℃ | ISO 11358 | |
| Density | 1.13 g/cm3p. 1: Density ISO 1183 23℃ g/cm3also in SUNLU, SUNLU PCL official product page (Chinese) | specimen not stated, ISO 1183As the sheet prints it: 23℃ ISO 1183 | |
| Melt mass-flow rate | 30 ± 10 g/10 minp. 1: Melt Mass-flow Rate ISO 1133 260℃/2.16 kg g/10 minalso in SUNLU, SUNLU PCL 产品资料 / Product informationalso in SUNLU, SUNLU PCL official product page (Chinese) | ISO 1133As the sheet prints it: 260℃/2.16 kg ISO 1133 | |
| Mould shrinkage orientation not stated | 1.3-1.6 %p. 1: Moulding Shrinkage ISO 294 23℃ %also in SUNLU, SUNLU PCL official product page (Chinese) | ISO 294As the sheet prints it: 23℃ ISO 294 | |
| SUNLU, SUNLU PCL 产品资料 / Product information1 valueThe same values also in SUNLU, TECHNICAL DATA SHEET ISO PCL. | |||
| Elongation at break XY | 800 %p. 1: 断裂伸长率(X-Y) Elongation at break, ISO527/2, 50mm/min, %, 800; p. 3: Note [1], specimen printing 45mm/s at80°C; p. 2: recommended nozzle75–85°Calso in SUNLU, TECHNICAL DATA SHEET ISO PCL | ISO 527As the sheet prints it: 50 mm/min ISO 527/2print settings[1] 测试样条打印速度 45 mm/s,打印温度 80 ℃。填充 100%,走线方式为 90 度。 | in the median |
| SUNLU, SUNLU PCL official product page (Chinese)1 value | |||
| Elongation at break orientation not stated | 800 %p. 1: 断裂伸长率(%) | no standard stated | not in the median: replaced by a newer edition of the sheet or by the data sheet, so not used in deciding |
Print settings
- Nozzle
- 75–85 °Cown data sheet
- Bed
- 20–40 °Cown data sheet
- Heated chamber
- not requiredown data sheet
- Drying
- 40–50 °C for 1 hown data sheet
- Hardened nozzle
- not stated
Differs in another document of this product, not used in deciding (a data sheet speaks before a product page, a newer edition before an older one): nozzle in SUNLU, SUNLU general filament guide (SUNLU wiki).
Its 4 print profiles, in the documents' words
- Nozzle 75-85℃; Bed /; Chamber Room Temperature; Drying /SUNLU, TECHNICAL DATA SHEET ISO PCLp. 2: Nozzle Temp.; p. 2: Plate Temp.; p. 2: Plate Material; p. 2: Room Temp.; p. 2: Drying Temp.
- Bed 该材料无需热床即可成功打印SUNLU, SUNLU PCL official product page (Chinese)p. 1: 无需热床,几乎不翘边; p. 1: 超低熔点,低打印温度
- Bed /; Chamber 常温; Drying /SUNLU, SUNLU PCL 产品资料 / Product informationp. 2: 打印平台温度 Print Platform Temp.; p. 2: 打印平台材料 Print Platform Material; p. 2: 环境温度 Room Temp.; p. 2: 烘干温度 Drying Temp.
- Nozzle 130-150℃; Bed 20-40℃ (Normal temperature is also acceptable); Drying 40-50℃; approximately 1 hourSUNLU, SUNLU general filament guide (SUNLU wiki)p. 1: drying; p. 1: PCL, Nozzle Print Temperature; p. 1: PCL, Print Platform Temperature
Price
Not in the price sample.
Its 5 documents
What the maker says (10)
- Good for
Decorative items, toys, accessories, and figurines
SUNLU, TECHNICAL DATA SHEET ISO PCLp. 1 - Benefits
Can be printed at a low temperature of 70°C, suitable for 3D printing pens, and can be reshaped repeatedly.
SUNLU, TECHNICAL DATA SHEET ISO PCLp. 1 - Benefits
可在 70℃低温下打印,打印笔用,可重复塑型
SUNLU, SUNLU PCL 产品资料 / Product informationp. 1 - Benefits
三绿PCL的低熔点使材料打印过程更加安全,适合教学与快速成型。
SUNLU, SUNLU PCL official product page (Chinese)p. 1 - Benefits
材料可重复塑形,灵活性高。
SUNLU, SUNLU PCL official product page (Chinese)p. 1 - Benefits
材料具有超低熔点,能够在较低的打印温度下顺利打印,确保整个打印过程更加安全,降低高温带来的潜在风险,适合各种打印环境。
SUNLU, SUNLU PCL official product page (Chinese)p. 1 - Printing advice
该材料无需热床即可成功打印,减少了对设备的依赖。
SUNLU, SUNLU PCL official product page (Chinese)p. 1 - Warping and shrinkage
打印过程中几乎不发生翘边现象,大大提高了打印稳定性和成功率,使打印过程更加轻松和高效。
SUNLU, SUNLU PCL official product page (Chinese)p. 1 - Benefits
具有出色的韧性,打印成型后可以反复塑形,适合进行二次加工和调整,保证了材料的长久耐用性。
SUNLU, SUNLU PCL official product page (Chinese)p. 1 - Benefits
无论是重复使用还是高强度应用,均能保持优异的表现。
SUNLU, SUNLU PCL official product page (Chinese)p. 1
Chemicals and environment (12)
- Organic solvent resistance: described in words
丙酮 Ketone 一般
Acetone · Acetone · specificSUNLU, SUNLU PCL 产品资料 / Product informationp. 2: Chemical resistance, 丙酮 Ketone agent/rating - Acid resistance: described in words
Weak Acid (pH 3-6) | Normal
Effect of weak acids · weakSUNLU, TECHNICAL DATA SHEET ISO PCLp. 1: Chemical Item/Class, Weak Acid (pH 3-6) agent/result cells - Acid resistance: described in words
Strong Acid (pH<3) | Bad
Effect of strong acids · strongSUNLU, TECHNICAL DATA SHEET ISO PCLp. 1: Chemical Item/Class, Strong Acid (pH<3) agent/result cells - Alkali resistance: described in words
Weak Bases (pH 8-10) | Normal
Effect of weak alkalis · weakSUNLU, TECHNICAL DATA SHEET ISO PCLp. 1: Chemical Item/Class, Weak Bases (pH 8-10) agent/result cells - Alkali resistance: described in words
Strong Bases (pH >10) | Bad
Effect of strong alkalis · strongSUNLU, TECHNICAL DATA SHEET ISO PCLp. 2: Chemical Item/Class, Strong Bases (pH >10) agent/result cells - Moisture sensitivity: described in words
Deionized Water | Excellent
SUNLU, TECHNICAL DATA SHEET ISO PCLp. 2: Chemical Item/Class, Deionized Water agent/result cells - Organic solvent resistance: described in words
Alcohol | Good
SUNLU, TECHNICAL DATA SHEET ISO PCLp. 2: Chemical Item/Class, Alcohol agent/result cells - Organic solvent resistance: described in words
Ketone | Good
SUNLU, TECHNICAL DATA SHEET ISO PCLp. 2: Chemical Item/Class, Ketone agent/result cells - Oil and grease resistance: described in words
Petroleum Fuels | Good
SUNLU, TECHNICAL DATA SHEET ISO PCLp. 2: Chemical Item/Class, Petroleum Fuels agent/result cells - Organic solvent resistance: described in words
Ester | Good
SUNLU, TECHNICAL DATA SHEET ISO PCLp. 2: Chemical Item/Class, Ester agent/result cells - Flammability: described in words
HB
SUNLU, TECHNICAL DATA SHEET ISO PCLp. 1: Properties, Flammability UL94,1.5mm - UV and outdoor: described in words
The product may yellow under the action of ultraviolet light, so it should be stored away from direct sunlight.
UVSUNLU, TECHNICAL DATA SHEET ISO PCLp. 4: Safety and Handling Precautions, UV yellowing/storage paragraph
iSANMATE Capa 6500 PolycaprolactoneStrength XY, MPa—Modulus XY, GPa—Izod notched, kJ/m²—HDT 0.45, °C—Price, CAD/kg—Nozzle, °C—Bed, °C—Chamber, °C—Drying, °C, h—
iSANMATE Capa 6500 PolycaprolactoneiSANMATE
Published values
| Property | As published | Conditions | On the Overview |
|---|---|---|---|
| iSANMATE, Capa™ 6500 Polycaprolactone Technical Data Sheet2 values | |||
| Elongation at break orientation not stated | 800 %p. 1: Tensile strain (break) | no standard stated | not in the median: set apart (never used to pass), test bar not described as printed |
| Melting temperature | 58.0 to 60.0 °Cp. 1: Melting temperature | no standard stated | |
Print settings
No print settings on file for this product.
No product matches "".
Not published by any product: tensile strength (Z) and HDT at 1.8 MPa.
Values are for the colour each sheet tested; pigment can change them.